• Single Glass AFM Media Filters: Superior sediment filtration removing up to 95% of particles down to 1 micron. As well as the efficient removal of hydrophobic hydrocarbons (oil & fats) organics and Microplastics. Duplex Glass AFM Media Filter for High Capacity Service Flow Rate: Sediment particle filtration to as low as 1 micron, removing hydrocarbons, organics and microplastics.
    • High quality stainless steel piping and frame construction
    • Dead zone free construction
    • Tank-less heating technology, removing risk of potential endotoxin accumulation
    • Remote monitoring and control functionality ensuring rapid response / support
    • Demand-rated control and water recycling / recovery technology
    • Flows up to 6.1 L/s
    • Automatic backwash via timer control (Adjustable settings of 4hr, 8hr, 24hr, weekly and monthly)
    • Extremely efficient screen cleaning ratio of 1:1 using point rotation principle
    • Standard 100 micron stainless steel screen (Silver coated to inhibit bacterial growth)
    • No interruption to water flow during screen cleaning
    • Can be mounted in vertical or horizontal pipe runs
    • Clear viewing glass enables full view of screen and backwash operation
    • BMS connection for operation, fault, and backwash status available
    • Fitted with DN80-DN200 screen for greater surface area
    • Minimum operating pressure: 200kPa
    • Pressure class: PN10
    • Flows up to 6.1 L/s
    • Automatic backwash via differential pressure and timer control
    • Extremely efficient screen cleaning ratio of 1:1 using point rotation principle
    • Standard 100 micron stainless steel screen (Silver coated to inhibit bacterial growth)
    • No interruption to water flow during screen cleaning
    • Can be mounted in vertical or horizontal pipe runs
    • Clear viewing glass enables full view of screen and backwash operation
    • BMS connection for operation, fault, and backwash status available
    • Fitted with DN80-DN200 screen for greater surface area
    • Minimum operating pressure: 200kPa
    • Pressure class: PN10
    • Flows up to 6.1 L/s
    • Extremely efficient screen cleaning ratio of 1:1 using point rotation principle
    • Standard 100 micron stainless steel screen (Silver coated to inhibit bacterial growth)
    • No interruption to water flow during screen cleaning
    • Can be mounted in vertical or horizontal pipe runs
    • Clear viewing glass enables full view of screen and backwash operation
    • Fitted with DN80-DN200 screen for greater surface area
    • Minimum operating pressure: 200kPa
    • Pressure class: PN10
    • Flows up to 1.5 L/s
    • Compact design ensures minimum installation disruption
    • Backwash cleaning process via rotating suction arms
    • 100 micron stainless steel screen
    • No interruption to water flow during screen cleaning
    • Can be mounted in vertical or horizontal pipe runs
    • Clear viewing glass enables full view of screen and backwash operation
    • Operating pressure range: 200 - 1600kPa
    • Flows up to 21.6 L/s
    • Automatic backwash via timer control (Adjustable settings of 4hr, 8hr, 24hr, weekly and monthly)
    • Extremely efficient screen cleaning ratio of 1:1 using point rotation principle
    • Standard 100 micron stainless steel screen (Silver coated to inhibit bacterial growth)
    • No interruption to water flow during screen cleaning
    • Can be mounted in vertical or horizontal pipe runs
    • Clear viewing glass enables full view of screen and backwash operation
    • BMS connection for operation, fault and backwash status available
    • Minimum operating pressure: 200kPa
    • Pressure class (25mm-DN65): PN16
    • Pressure class (DN80-DN200): PN10
    • Flows up to 55.5 L/s
    • Automatic backwash via differential pressure and timer control
    • Extremely efficient screen cleaning ratio of 1:1 using point rotation principle
    • Standard 100 micron stainless steel screen (Silver coated to inhibit bacterial growth)
    • No interruption to water flow during screen cleaning
    • Can be mounted in vertical or horizontal pipe runs
    • Clear viewing glass enables full view of screen and backwash operation
    • BMS connection for operation, fault, and backwash status available
    • Minimum operating pressure: 200kPa
    • Pressure class (25mm-DN65): PN16
    • Pressure class (DN80-DN200): PN10
    • Flows up to 55.5 L/s
    • Extremely efficient screen cleaning ratio of 1:1 using point rotation principle
    • Standard 100 micron stainless steel screen (Silver coated to inhibit bacterial growth)
    • No interruption to water flow during screen cleaning
    • Can be mounted in vertical or horizontal pipe runs
    • Clear viewing glass enables full view of screen and backwash operation
    • Minimum operating pressure: 200kPa
    • Pressure class (25mm-DN65): PN16
    • Pressure class (DN80-DN200): PN10
    • Flows up to 4.7 L/s
    • Backwash cleaning process via rotating suction arms
    • 100 micron stainless steel screen
    • No interruption to water flow during screen cleaning
    • Flows up to 4.7 L/s
    • Automatic backwash via timer control (Adjustable settings of 24hr, weekly, monthly, and 2 monthly)
    • Backwash cleaning process via rotating suction arms
    • 100 micron stainless steel screen
    • No interruption to water flow during screen cleaning
    • Can be mounted in vertical or horizontal pipe runs
    • Clear viewing glass enables full view of screen and backwash operation
    • BMS connection for operation and fault status as standard
    • Minimum operating pressure: 200kPa
    • Pressure class: PN16
    • Permeate flows up to 36,000 L/day
    • Grundfos high pressure pump
    • 5 micron sediment pre-filter
    • Float switch, feed and permeate water pressure switches
    • 4040 RO membranes
    • EConnect controller - online live system performance monitoring
    • Options - antiscalant dosing, permeate membrane rinse, raw water blending
    • Permeate conductivity and temperature sensors
    • Permeate, drain and recycle water rotameters
    • Process controller with status of level, pressure and stop switches; permeate conductivity and temperature readout, alarm signal
Go to Top