- Addresses hard water problems such as calcification, scaling, and spotting by removing magnesium and calcium hardness minerals and discarding them to drain.
- Single or multiple softener configurations
- 5-cycle automatic softener valves
- Water meter regeneration initiation
- Single, alternating, or twin metered controls
- Sequential or parallel controls for multiple softeners
- Free standing FRP fiberglass wrapped polyethylene resin tanks
- Heavy duty polyethylene brine tanks and lids
- Food grade high capacity softener resin
-
-
Single Sediment Removal Filter:
- High flow sediment filtration down to 5 micron with superior loading capacity.
- Suitable for dirt, rust, sand, and other fine particles.
- High flow sediment filtration down to 5 micron with superior loading capacity.
- Suitable for dirt, rust, sand, and other fine particles.
-
Single Glass AFM Media Filters: Superior sediment filtration removing up to 95% of particles down to 1 micron. As well as the efficient removal of hydrophobic hydrocarbons (oil & fats) organics and Microplastics. Duplex Glass AFM Media Filter for High Capacity Service Flow Rate: Sediment particle filtration to as low as 1 micron, removing hydrocarbons, organics and microplastics.
-
- Reduces Chlorine, chlorine taste and odour. Decreases organic based colour, taste, odour, pesticides and chemicals.
- Media filtration using a bed of carbon, crushed glass, anthracite, crushed granite or other material.
- Fully automatic media filtration
- Used to filter water for various applications e.g. drinking, swimming pools, aquaculture, irrigation, stormwater management, oil and gas operations.
-
- Flows up to 6.1 L/s
- Automatic backwash via differential pressure and timer control
- Extremely efficient screen cleaning ratio of 1:1 using point rotation principle
- Standard 100 micron stainless steel screen (Silver coated to inhibit bacterial growth)
- No interruption to water flow during screen cleaning
- Can be mounted in vertical or horizontal pipe runs
- Clear viewing glass enables full view of screen and backwash operation
- BMS connection for operation, fault, and backwash status available
- Fitted with DN80-DN200 screen for greater surface area
- Minimum operating pressure: 200kPa
- Pressure class: PN10
-
- Flows up to 6.1 L/s
- Automatic backwash via timer control (Adjustable settings of 4hr, 8hr, 24hr, weekly and monthly)
- Extremely efficient screen cleaning ratio of 1:1 using point rotation principle
- Standard 100 micron stainless steel screen (Silver coated to inhibit bacterial growth)
- No interruption to water flow during screen cleaning
- Can be mounted in vertical or horizontal pipe runs
- Clear viewing glass enables full view of screen and backwash operation
- BMS connection for operation, fault, and backwash status available
- Fitted with DN80-DN200 screen for greater surface area
- Minimum operating pressure: 200kPa
- Pressure class: PN10
-
- Flows up to 6.1 L/s
- Extremely efficient screen cleaning ratio of 1:1 using point rotation principle
- Standard 100 micron stainless steel screen (Silver coated to inhibit bacterial growth)
- No interruption to water flow during screen cleaning
- Can be mounted in vertical or horizontal pipe runs
- Clear viewing glass enables full view of screen and backwash operation
- Fitted with DN80-DN200 screen for greater surface area
- Minimum operating pressure: 200kPa
- Pressure class: PN10
-
- Flows up to 55.5 L/s
- Automatic backwash via differential pressure and timer control
- Extremely efficient screen cleaning ratio of 1:1 using point rotation principle
- Standard 100 micron stainless steel screen (Silver coated to inhibit bacterial growth)
- No interruption to water flow during screen cleaning
- Can be mounted in vertical or horizontal pipe runs
- Clear viewing glass enables full view of screen and backwash operation
- BMS connection for operation, fault, and backwash status available
- Minimum operating pressure: 200kPa
- Pressure class (25mm-DN65): PN16
- Pressure class (DN80-DN200): PN10
-
- Flows up to 21.6 L/s
- Automatic backwash via timer control (Adjustable settings of 4hr, 8hr, 24hr, weekly and monthly)
- Extremely efficient screen cleaning ratio of 1:1 using point rotation principle
- Standard 100 micron stainless steel screen (Silver coated to inhibit bacterial growth)
- No interruption to water flow during screen cleaning
- Can be mounted in vertical or horizontal pipe runs
- Clear viewing glass enables full view of screen and backwash operation
- BMS connection for operation, fault and backwash status available
- Minimum operating pressure: 200kPa
- Pressure class (25mm-DN65): PN16
- Pressure class (DN80-DN200): PN10
-
- Flows up to 55.5 L/s
- Extremely efficient screen cleaning ratio of 1:1 using point rotation principle
- Standard 100 micron stainless steel screen (Silver coated to inhibit bacterial growth)
- No interruption to water flow during screen cleaning
- Can be mounted in vertical or horizontal pipe runs
- Clear viewing glass enables full view of screen and backwash operation
- Minimum operating pressure: 200kPa
- Pressure class (25mm-DN65): PN16
- Pressure class (DN80-DN200): PN10
-
- Flows up to 4.7 L/s
- Automatic backwash via timer control (Adjustable settings of 24hr, weekly, monthly, and 2 monthly)
- Backwash cleaning process via rotating suction arms
- 100 micron stainless steel screen
- No interruption to water flow during screen cleaning
- Can be mounted in vertical or horizontal pipe runs
- Clear viewing glass enables full view of screen and backwash operation
- BMS connection for operation and fault status as standard
- Minimum operating pressure: 200kPa
- Pressure class: PN16
-
- Flows up to 4.7 L/s
- Backwash cleaning process via rotating suction arms
- 100 micron stainless steel screen
- No interruption to water flow during screen cleaning